=1.02831
式中qnf—暖风器吸热量,按下失计算:
qnf=αnf(hnf– h′nf)=0.03235(3164-697)=79.8 kJ/kg 相应于1㎏标煤的输入热量QSb:
QSb=29300r=29300×1.02831=30129.6 kJ/kg
发电标准煤耗bs:
bs=3600/(ηcp QSb)=3600/(0.37465×30129.6)=0.31892 kJ/kwh 6.全厂热耗率qcp
qcp= bs·29300=0.31892×29300=9344.356 kJ/kwh
7.全厂供电标准煤耗bsn
bsn= bs/( 1-ε)=0.31892/(1-0.07) =0.3341935 kJ/kwh
式中ε—厂用电率。 三、反平衡校核
为检查计算结果的正确性,以下做全厂反平衡校核计算。校核目标为气轮机的内功ωi。反平衡计算中的各量均相应于1㎏气轮机进汽。
1. 锅炉输入热量qr
qr=q1/ηb=2681.1/0.925
=2898.378378kJ/kg
2. 锅炉损失Δqb
Δqb=(1-ηb)qr=(1-0.925)×2898.378378
=217.3783784 kJ/kg
3. 排污损失Δqbl
Δqbl=αbl(hbl- hma)=0.005408×(1760.3-83.7)
=9.067 kJ/kg
式中hma—化学补充水的比焓,hma=83.7
4. 全厂工质渗透损失ΔqL
ΔqL=αL(hL- hma)=0.0162263(3397.2-83.7)
=53.74 kJ/kg
5. 厂用汽损失Δqpl
Δqpl=αpl(hpl- hma)=0.01081(3164-83.7)
=33.29 kJ/kg
6. 凝汽流冷源损失Δqc
Δqc=αc(hc- h'c)=0.51658(2315.6-137.3)
21
=1125.3 kJ/kg
7. 小汽机冷源损失Δqxj
Δqxj=αc,xj(hc,xj- h'c)=0.03613(2422.6-137.3)
=72.28 kJ/kg
8. 化学补充水冷源损失Δqma
Δqma=αma(hma- h'c)=0.03244(83.7-137.3)
=-1.7388 kJ/kg
9. 低加H8疏水冷源损失Δqd'8
Δqd'8=αd,8(hd,8- h'c)=0.1238(160.27-137.3)
=2.8437 kJ/kg
10. 轴封加热器疏水冷源损失Δqd,sg
Δqd,sg=αd,8g(hd,8g- h'c)=0.0087455(415-137.3)
=2.4286 kJ/kg
11. W气流冷源损失Δqsg,W
Δq=α(h-h'c)
=0.0039263(3152.1-137.3) =11.837 kJ/kg
12. 暖风器损失Δqnf
Δqnf=αnf(hnf- h'nf)=0.032354439(3164-697)
=80.4 kJ/kg
13. 管道散热损失Δqp
Δqp=αb(hb- h0)+αrh(h"rh- hrh)
=1.0162263(3399.3-3397.2)+0.8235(3543-3538.9029)=8.56 kJ/kg
14. 轴封器散热损失
ΣΔqsg=(αsg,L1+αsg,L1+αsg,L1)( h0- h sg,L1)+ αsg,S( hjyx- h sg,S) +αsg,W( hjyx- h sg,W)
=(0.001429+0.0010320)(3397.2-3024.3)+0.0006244
(3152.1-3217.7)+0.0028622(3152.1-1716) =2.073 kJ/kg
损失之和ΣΔqi
ΣΔqi=Δqb不+Δqbl+ΔqL+Δqc+Δqxj+Δqma+Δqd,8+Δqd,sg+Δqsg,W+Δqnf+ΔqP+ΣΔq
=217.4+9.067+53.74+33.29+1125.3+72.28-1.7388+2.8437
22
+2.4286+11.837+79.96+8.56+2.073 =1611.82 kJ/kg 汽轮机内功ω'i
ω'i=qr-ΣΔqi=2898.5-1611.82=1286.68kJ/kg 正、反平衡相对误差δωi
δωi=(1286.68-1386.66)/1286.66=0.0016% `
计算无误。
23
百度搜索“77cn”或“免费范文网”即可找到本站免费阅读全部范文。收藏本站方便下次阅读,免费范文网,提供经典小说教育文库热力发电厂课程设计 - 660MW凝汽式机组全厂原则性热力系统计算(5)在线全文阅读。