MegaCli 命令使用指南
1. 命令使用:
2. #/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL 查raid级别 3. #/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL 查raid卡信息 4. #/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL 查看硬盘信息 5. #/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aAll 查看电池信息
6. #/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL 查看raid卡日志 7. #/opt/MegaRAID/MegaCli/MegaCli64 -adpCount 【显示适配器个数】
8. #/opt/MegaRAID/MegaCli/MegaCli64 -AdpGetTime –aALL 【显示适配器时间】 9. #/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aAll 【显示所有适配器信息】 10. #/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -LALL -aAll 【显示所有逻辑磁盘组信息】 11. #/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aAll 【显示所有的物理信息】
12. #/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL |grep 'Charger Status'
【查看充电状态】
13. #/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】 14. #/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】 15. #/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU设计参数】 16. #/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuProperties -aALL 【显示当前BBU属性】 17. #/opt/MegaRAID/MegaCli/MegaCli64 -cfgdsply -aALL 【显示Raid卡型号,Raid设置,Disk相关信
息】
18. 3.磁带状态的变化,从拔盘,到插盘的过程中。 19. Device |Normal|Damage|Rebuild|Normal
20. Virtual Drive |Optimal|Degraded|Degraded|Optimal
21. Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online 22. 4.查看磁盘缓存策略
23. #/opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -Cache -L0 -a0 24. or
25. #/opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -Cache -L1 -a0 26. or
27. #/opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -Cache -LALL -a0 28. ro
29. #/opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -Cache -LALL -aALL 30. ro
31. #/opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -DskCache -LALL -aALL 32. 5.设置磁盘缓存策略 33. 缓存策略解释: 34.
35. WT (Write through 36. WB (Write back) 37. NORA (No read ahead)
38. RA (Read ahead)
39. ADRA (Adaptive read ahead) 40. Cached 41. Direct 42. 例子:
43. #/opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp WT|WB|NORA|RA|ADRA -L0 -a0 44. or
45. #/opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp -Cached|-Direct -L0 -a0 46. or
47. enable / disable disk cache
48. #/opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp -EnDskCache|-DisDskCache -L0 -a0 49. 6.创建一个 raid5 阵列,由物理盘 2,3,4 构成,该阵列的热备盘是物理盘 5
50. #/opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r5 [1:2,1:3,1:4] WB Direct -Hsp[1:5] -a0 51. 7.创建阵列,不指定热备
52. #/opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r5 [1:2,1:3,1:4] WB Direct -a0 53. 8.删除阵列
54. #/opt/MegaRAID/MegaCli/MegaCli64 -CfgLdDel -L1 -a0 55. 9.在线添加磁盘
56. #/opt/MegaRAID/MegaCli/MegaCli64 -LDRecon -Start -r5 -Add -PhysDrv[1:4] -L1 -a0 57. 10.阵列创建完后,会有一个初始化同步块的过程,可以看看其进度。 58. #/opt/MegaRAID/MegaCli/MegaCli64 -LDInit -ShowProg -LALL -aALL 59. 或者以动态可视化文字界面显示
60. #/opt/MegaRAID/MegaCli/MegaCli64 -LDInit -ProgDsply -LALL -aALL 61. 11.查看阵列后台初始化进度
62. #/opt/MegaRAID/MegaCli/MegaCli64 -LDBI -ShowProg -LALL -aALL 63. 或者以动态可视化文字界面显示
64. #/opt/MegaRAID/MegaCli/MegaCli64 -LDBI -ProgDsply -LALL -aALL 65. 12.指定第 5 块盘作为全局热备
66. #/opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Set [-EnclAffinity] [-nonRevertible] -PhysDrv
[1:5] -a0
67. 13.指定为某个阵列的专用热备
68. #/opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Set [-Dedicated [-Array1]] [-EnclAffinity] [-nonRevertible] -PhysDrv[1:5] -a0 69. 14.删除全局热备
70. #/opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Rmv -PhysDrv[1:5] -a0 71. 15.将某块物理盘下线/上线
72. #/opt/MegaRAID/MegaCli/MegaCli64 -PDOffline -PhysDrv [1:4] -a0 73. #/opt/MegaRAID/MegaCli/MegaCli64 -PDOnline -PhysDrv [1:4] -a0 74. 16.查看物理磁盘重建进度
75. #/opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -ShowProg -PhysDrv [1:5] -a0 76. 或者以动态可视化文字界面显示
77. #/opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -ProgDsply -PhysDrv [1:5] -a0 78.
79. 磁带状态的变化,从拔盘,到插盘的过程中:
80. Device |Normal|Damage|Rebuild|Normal
81. Virtual Drive |Optimal|Degraded|Degraded|Optimal
82. Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online
83.1、 查看RAID级别
84.
85.2、 查看RAID卡信息,主要输出RAID卡的一些配置信息
86.87.
88. RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 1.086 TB
State : Optimal Strip Size : 128 KB
Number Of Drives per span:4 //表示每4个物理盘做成一个RAID1盘组 Span Depth : 2 //表示共2个RAID1盘组做成了RAID10
89.
90.3、 查看所有硬盘的信息 91./opt/MegaCli64 -pdlist –aALL
92.
93.4、 查看当前raid缓存状态,raid缓存状态设置为wb的话要注意电池放电事宜,
设置电池放电模式为自动学习模式
94./opt/MegaRAID/MegaCli/MegaCli64 -ldgetprop -dskcache -lall -aall
95.
96.5、 raid 电池设置相关
97.查看电池状态信息(Display BBU Status Information)
MegaCli -AdpBbuCmd -GetBbuStatus -aN|-a0,1,2|-aALL MegaCli -AdpBbuCmd -GetBbuStatus -aALL
98.查看电池容量(Display BBU Capacity Information)
MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aN|-a0,1,2|-aALL MegaCli -AdpBbuCmd -GetBbuCapacityInfo –aALL
99.查看电池设计参数(Display BBU Design Parameters)
MegaCli -AdpBbuCmd -GetBbuDesignInfo -aN|-a0,1,2|-aALL MegaCli -AdpBbuCmd -GetBbuDesignInfo –aALL
100.
查看电池属性(Display Current BBU Properties)
MegaCli -AdpBbuCmd -GetBbuProperties -aN|-a0,1,2|-aALL MegaCli -AdpBbuCmd -GetBbuProperties –aALL
101.
设置电池为学习模式为循环模式(Start BBU Learning Cycle)
Description Starts the learning cycle on the BBU. No parameter is needed for this option.
MegaCli -AdpBbuCmd -BbuLearn -aN|-a0,1,2|-aALL
102.
设置磁盘的缓存模式和访问方
式 (Change Virtual Disk Cache and Access Parameters)
Description Allows you to change the following virtual disk parameters: -WT (Write through), WB (Write back): Selects write policy.
-NORA (No read ahead), RA (Read ahead), ADRA (Adaptive read ahead): Selects read policy.
-Cached, -Direct: Selects cache policy. -RW, -RO, Blocked: Selects access policy. -EnDskCache: Enables disk cache. -DisDskCache: Disables disk cache.
MegaCli -LDSetProp { WT | WB|NORA |RA | ADRA|-Cached|Direct} | {-RW|RO|Blocked} | {-Name[string]} |
{-EnDskCache|DisDskCache} –Lx | -L0,1,2|-Lall -aN|-a0,1,2|-aALL MegaCli -LDSetProp WT -L0 -a0
103.
显示磁盘缓存和访问方式(Display Virtual Disk Cache and Access Parameters)
MegaCli -LDGetProp -Cache | -Access | -Name | -DskCache -Lx|-L0,1,2| -Lall -aN|-a0,1,2|-aALL
Displays the cache and access policies of the virtual disk(s): -WT (Write through), WB (Write back): Selects write policy.
百度搜索“77cn”或“免费范文网”即可找到本站免费阅读全部范文。收藏本站方便下次阅读,免费范文网,提供经典小说综合文库MegaCli 命令使用指南在线全文阅读。
相关推荐: