2.3 操作环境
2.3.1 DS4800 Disk System Model 88 (1815-88A) ? 温度 (operating):
? 10 to 35 degrees C (50 to 95 degrees F) at 0 to 914 m (0-3,000 ft) ? 10 to 32 degrees C (50 to 90 degrees F) at 914 to 2,133 m (3000-7000 ft)
? 温度(storage):
? 1 to 60 degrees C (33 to 140 degrees F) at 0 to 914 m (0-3,000 ft)
? 相关湿度 (operating):
? 8% to 80%
? 相关湿度 (storage):
? 5% to 80%
? 电源 (per power supply, system rating):
? Voltage range - (100-240 V ac) ? Operating current (5.4 - 2.25 amperes) ? Power (540 watts) ? Frequency (50/60 Hz)
? 热耗: 804 BTU per hour
? 噪音 (normal operation): 6.75 bels
2.3.2 EXP810存储扩展单元(1812-81A) ? 温度(operating):
? 10 to 35 degrees C (50 to 95 degrees F) at 0-914 m (0-3,000 ft) ? 10 to 32 degrees C (50 to 90 degrees F) at 914 - 2,133 m (3000-7000 ft)
? 相关湿度 (operating):
? 8% to 80%
? 电源 (per power supply):
? Voltage range - nominal (100 - 240 V ac)
? Operating current (1.95 amperes with 115 Vac input) ? Power (448.5 watts) ? Frequency (50/60 Hz)
? 热耗: 1569.94 BTU per hour (fully configured) ? 噪音 (normal operation): 6.8 bels
3 DS4800存储分配规则
注:DS4800微码版本:
Storage Manager 版本: SMIA-WS32-09.23.35.01.exe DS4800 Controller Firmware: 06.23.05.00 DS4800 Controller NVRAM : N1815D480R923V09
? 随机访问比较多的应用划分磁盘时建议做RAID 0+1,顺序访问的应用做RAID5; ? 访问量比较大的LUN均衡到多个RAID组中,避免热点盘过于集中;
? 尽量分配同一容量的LUN,对于同一机器的不同属性的应用(DB/FS),可分配不同
容量的LUN;
? 数据空间跟索引空间建议放在不同的RAID组中,数据放在RAID5中,日志放在
RAID10中;
? 对于HP需要做MC的双机,分配一个容量为100M的LUN作为锁盘;
? 在主机端认到PV后,将PV与LUN、LUN与Host之间的对应关系作成表格交予系统
管理员,以利于主机做条带化;
? 针对多应用的情况可以来自于不同的RAID 组。
3.1 IP 地址
根据网络地址规划,为DS4800分配2个主IP地址:
Controller A IP: ________________________ (默认值:192.168.128.101) Controller B IP: __________ _________ (默认值:192.168.128.102)
3.2 与扩展单元的连接规划
A. 1个DS4800和8个扩展单元— Recommended cabling
B. 1个DS4800和14个EXP810扩展单元— Recommended cabling
注:
? 新增A:含7个EXP810,根据连线规则A的方式连线 ? 新增B:含10个EXP810,根据连线规则B的方式连线 ? 新增C:含12个EXP810,根据连线规则B的方式连线 ? 新增D:含13个EXP810,根据连线规则B的方式连线
百度搜索“77cn”或“免费范文网”即可找到本站免费阅读全部范文。收藏本站方便下次阅读,免费范文网,提供经典小说综合文库IBM-存储-DS4800使用及维护手册 - 图文(2)在线全文阅读。